Choose a mechanical test plug when you know the exact inside diameter and need a firm seal or a high test pressure: CRYSTAL® mechanical plugs go up to 15,000 psig (1,034 barg). Choose an inflatable plug when one plug must cover several pipe sizes or the line is large: CRYSTAL® inflatable plugs cover 2″–72″ (50–1,800 mm) at up to 87 psi (6 bar).
You tighten a nut and a rubber ring expands against the pipe wall. One plug fits one size. Firm, simple, and the only choice for very high pressure.
You pump air into a reinforced rubber body until it grips the pipe. One plug covers a range of sizes, and large lines are easy to reach.
Meet the plugs
CL-PLUG™Center-lock, 0.5″–18″, up to 3.4 barView product ›
ML-PLUG™Multi-lock for 17″–80″ boresView product ›
IN-MAX™High pressure, up to 1,034 barView product ›
BALL-PLUG™Balloon plug for drains, 2″–24″View product ›
INFLA-TEST™Multi-size with bypass, 2.5 barView product ›
INFLA-PTEST™High-pressure inflatable, 6 barView product ›How much pressure each plug holds
Maximum test pressure by plug
Bar, log scale. Blue = inflatable, navy = mechanical.
Side by side
| Mechanical | Inflatable | |
|---|---|---|
| How it seals | Nut expands a rubber ring | Air inflates a reinforced rubber body |
| Sizes in stock | 3/8″–80″ (DN10–2,000 mm) | 2″–72″ (50–1,800 mm) |
| Made to order | Up to 120″ (3,000 mm) | Up to 165″ (4,200 mm) |
| Sizes per plug | One | A range (INFLA models) |
| Highest pressure | Up to 1,034 bar (IN-MAX™) | 6 bar (INFLA-PTEST™) |
| Bypass | — | Single or double (INFLA-TEST™) |
Choose mechanical when
- You know the inside diameter and the bore is round and clean.
- The test is above 6 bar, for example a hydrostatic test to code. Only the MAX range goes that high.
- You test a bend: ELBOW-MAX™ seals inside elbows (see testing elbows without welding).
- You want a light plug for drain work: ALU-PLUG™.
Choose inflatable when
- One plug must cover several sizes on the job: each INFLA-TEST™ model covers a range.
- The line is large: up to 72″ (1,800 mm) from stock.
- Flow must pass, or you fill the line through the plug: pick a bypass model.
- You block a sewer for a short time: BALL-PLUG™ or INFLA-STOP™. Check the back pressure first.
A contractor tests 6″ PVC drains at 0.5 bar. CL-PLUG™ (up to 3.4 bar) or INFLA-TEST™ (2.5 bar) both work. BALL-PLUG™ is rated 0.15–0.2 bar, so it is too low for this test.
Large diameters (17″ and up)
ML-PLUG™ covers 17″–80″ at up to 0.34 bar. INFLA models reach 72″ at 2.5 or 6 bar. On a large line that needs more than 0.34 bar, ask us about an INFLA model or a made-to-order plug.
Air stores far more energy than water. Prefer water whenever the specification allows: read hydrostatic vs pneumatic testing and the force on a test plug.
Four questions before you order
- What is the real inside diameter? Measure it.
- What test pressure? Use the test pressure calculator.
- Water or air?
- One size or many?
Standard sizes are ready for pickup in Jeddah, Riyadh and Dammam. Need the test done for you? See our hydrostatic testing service.
Figures are taken from GRF product data sheets. Always follow your project specification and the plug instructions.