DS-PLUG™ Double-Seal Pipe Test Plug

Steel center-lock test plug with two seals. It sits deeper in the pipe, and the two seals centre it for a steadier, more stable seal during low-pressure air and water tests. Nominal sizes 1.5″ – 18″ (40 – 450 mm), fitting pipe I.D. 1.5″ – 20″ (37 – 495 mm); larger sizes on request.

Additional information

Size range

1.5″ – 18″ (40 – 450 mm)

Fits pipe I.D.

1.5″ – 20″ (37 – 495 mm)

Max. back pressure

Up to 30 psi (2.07 bar), by size

Body material

Steel, zinc-plated

Seals

Double (two seals)

Nominal size1.5″ – 18″40 – 450 mm
Fits pipe I.D.1.5″ – 20″37 – 495 mm · 20 sizes
Max. back pressureup to 30 psi2.07 bar, by size
SealsTwo rubber sealsdeeper insertion, self-centring
BodyZinc-plated steel90-hour salt spray test

DS-PLUG™ is our center-lock steel test plug with a second seal. The longer body goes further into the pipe, and the two rubber seals hold it square and centred in the bore. The result is a steadier plug that stays in line during the test, in long runs, uneven bores and joints where a single seal can tilt.

Turn the T-handle and the plates squeeze both seals against the pipe wall. The waterway lets you fill, vent and drain the line and release back pressure before you remove the plug. The back-pressure limits are the same as our single-seal plug: always check the value for your size.

Key features

  • Two seals centre the plug in the bore
  • Deeper insertion for a steadier, more stable seal
  • Steel body, zinc-plated to a 90-hour salt spray test
  • Thrust washers on 9″ (225 mm) and above
  • Waterway (½″ or 1″) to fill, vent, drain and release back pressure
  • Fits PVC, GRP, MDPE / HDPE and carbon steel pipes
  • Larger sizes and chemical-resistant seals on request

How to use

Seven steps, one plug.

  1. Know the plugTwo rubber seals sit on one body. Tightening the centre nut squeezes both seals against the pipe wall.
  2. Confirm the sizeMeasure the pipe I.D. and pick the size whose range covers it.
  3. Clean the pipeRemove dirt, scale and burrs from the pipe end so both seals sit on a clean wall.
  4. Insert the plugPush the plug in until both seals are inside the pipe, square to the pipe axis. It is made to sit further inside.
  5. Tighten to sealTurn the T-handle until both seals press firmly on the pipe wall.
  6. Fill & testConnect the hose and gauge to the waterway, fill and vent, then raise the pressure and hold it for the test time.
  7. Release & removeRelease the pressure, drain the line, loosen the T-handle and pull the plug out. Check both seals before the next test.

Sizes & part numbers

Find your size.

Enter your pipe inner diameter: every size whose sealing range covers it is highlighted. Part numbers are for steel, double seal, single nozzle; other versions on request.

P/N Nominal Fits I.D. Min. insertion Overall length Waterway Max. back pressure Approx. weight
110003 1.5″ · 40 mm 1.5 – 2″37 – 50 mm 2.4″62 mm 5.5″140 mm ½″ 30 psi2.07 bar 0.25 kg
110015 2″ · 50 mm 2 – 2.4″50 – 61 mm 2.6″66 mm 5.5″140 mm ½″ 30 psi2.07 bar 0.28 kg
110027 2.5″ · 65 mm 2.4 – 3″61 – 75 mm 2.6″67 mm 5.5″140 mm ½″ 30 psi2.07 bar 0.46 kg
110039 3″ · 75 mm 2.9 – 3.3″73 – 85 mm 2.7″68 mm 5.5″140 mm ½″ 20 psi1.38 bar 0.49 kg
110051 3.5″ · 89 mm 3.3 – 4″84 – 100 mm 3.2″82 mm 5.5″140 mm ½″ 15 psi1.03 bar 0.68 kg
110063 4″ · 100 mm 3.7 – 4.3″94 – 108 mm 3″76 mm 5.5″140 mm ½″ 10 psi0.69 bar 0.70 kg
110075 4.5″ · 114 mm 4 – 5″110 – 125 mm 3.1″80 mm 5.5″140 mm ½″ 10 psi0.69 bar 1.10 kg
110087 5″ · 125 mm 4.9 – 5.5″124 – 139 mm 2.9″74 mm 5.5″140 mm ½″ 10 psi0.69 bar 1.25 kg
110099 6″ · 150 mm 6 – 6″150 – 160 mm 3.1″80 mm 5.5″140 mm ½″ 10 psi0.69 bar 1.50 kg
110111 7″ · 175 mm 6.9 – 8″175 – 200 mm 3.6″92 mm 8.3″210 mm 1″ 7 psi0.48 bar 2.65 kg
110123 8″ · 200 mm 7.7 – 8.5″195 – 215 mm 3.6″92 mm 8.3″210 mm 1″ 7 psi0.48 bar 2.70 kg
110135 9″ · 225 mm 8.3 – 9.1″210 – 230 mm 3.6″92 mm 8.3″210 mm 1″ 7 psi0.48 bar 3.45 kg
110147 10″ · 250 mm 9.6 – 10″245 – 260 mm 4.3″110 mm 8.3″210 mm 1″ 7 psi0.48 bar 4.90 kg
110159 11″ · 275 mm 9.4 – 11″240 – 282 mm — — 1″ 7 psi0.48 bar —
110171 12″ · 300 mm 12 – 13″296 – 320 mm 6.7″170 mm 8.3″210 mm 1″ 7 psi0.48 bar 6.75 kg
110183 13″ · 325 mm 11 – 14″290 – 345 mm — — 1″ 7 psi0.48 bar —
110195 14″ · 350 mm 13 – 15″340 – 385 mm 6.7″170 mm 12.2″310 mm 1″ 5 psi0.34 bar 11.40 kg
110207 15″ · 375 mm 15 – 16″370 – 415 mm 7.9″200 mm 12.2″310 mm 1″ 5 psi0.34 bar 12.20 kg
110219 16″ · 400 mm 15 – 17″390 – 430 mm 7.7″195 mm 12.2″310 mm 1″ 5 psi0.34 bar 13.90 kg
110231 18″ · 450 mm 18 – 19″448 – 495 mm 9.8″250 mm 16.1″410 mm 1″ 5 psi0.34 bar 18.50 kg

Back pressure is the pressure inside the line acting on the plug. It is the installer’s responsibility never to exceed the value for your size; secure the plug against movement during the test. Insertion, length and weight for 11″ and 13″ on request.

Applications

Where it works.

Leak testing of drain, sewer and waste pipes
Air and water tests on long or uneven pipe sections
Works in PVC, GRP, MDPE / HDPE and carbon steel pipes
Manhole and chamber connections
Residential, commercial and municipal drainage

My project 0

Need a different size or pressure rating?

Send us the pipe I.D., material and test pressure. We will confirm the right plug and lead time.

Request a quote →