FLANGE-WELD™ Flange Weld Test & Isolation Plug

Mechanical plug for flange-to-pipe welding and testing. It bolts to the flange like a blind flange, seals inside the pipe beyond the weld and lets you purge, isolate, weld and test with one tool. Test pressure up to 2,250 psig (155 barg) by flange class; standard part numbers 6″ – 24″ (DN150 – DN600) in ANSI class 150, 300 and 600.

Additional information

Standard sizes

6″ – 24″ (DN150 – DN600); 3/8″ – 48″ on request

Flange classes

ANSI 150, 300, 600

Max. test pressure

450 psig (31 barg) class 150; 1,125 psig (77.6 barg) class 300; 2,250 psig (155 barg) class 600

Configuration

Weld plug / test plug

Purge

Inert gas through the ported centre shaft

Part numbers

640001 – 640027

Max. test pressure2,250 psig155 barg · class 600
Flange classesANSI 150 · 300 · 600450 · 1,125 · 2,250 psig
Standard sizes6″ – 24″DN150 – DN600
Temperature−26 °F to +180 °F−32 °C to +82 °C
Use4 in 1purge · isolate · weld · test

FLANGE-WELD™ is a mechanical plug for flange-to-pipe welding and hydrostatic testing. It bolts to the flange face with a gasket, like a blind flange, and its expanding seal locks inside the pipe beyond the weld. Only the small zone between the plate and the seal is filled and tested, so you never pressurise the whole line.

It works in two set-ups. As a weld plug, it isolates the line while you weld the flange to the pipe: the ported centre shaft lets you monitor upstream pressure and purge the weld area with inert gas. As a test plug, it hydrotests the finished weld, up to the maximum pressure for the flange class.

One tool covers purging, isolation, welding and testing, with very little water and no full-line pressurisation, which cuts test time on fabrication and maintenance work.

Key features

  • 4 in 1: purge, isolate, weld and test with one tool
  • Bolts to the flange like a blind flange, with a gasket
  • Expanding seal locks inside the pipe beyond the weld
  • Ported centre shaft for inert-gas purge or upstream monitoring
  • Test pressure by ANSI class: 450 psig (31 barg) for 150, 1,125 psig (77.6 barg) for 300, 2,250 psig (155 barg) for 600
  • Localised test with minimal water; no full-line pressurisation
  • Seal clearance of ½″ (12.7 mm) for weld spatter in the bore
  • Other sizes (3/8″ – 48″) and ratings on request

How to use

Eight steps, one flange.

  1. Know the toolThe plug bolts to the pipe flange like a blind flange. Its expanding seal sits inside the pipe, beyond the weld. Only the zone between the plate and the seal is tested.
  2. Insert with gasketCheck the seal and compression rings match the pipe size and schedule. Put the gasket on the flange face, slide the plug in and turn it so the vent port is at the top.
  3. Bolt to the flangeFit the flange bolts and tighten them in a cross pattern so the gasket seals evenly.
  4. Expand the sealTighten the hex nut on the centre shaft to the normal torque in the table (never above the maximum). The seal swells out and locks against the pipe wall beyond the weld.
  5. Fill & ventRemove both port plugs and connect water at the bottom port. Air escapes at the top; when water comes out of the top, the zone is full, so close it again.
  6. Pressurise & holdFit the gauge on the fill line. Raise slowly to the test pressure, never above the limit for the flange class, and hold it at least 5 minutes so the parts settle before you close the valve.
  7. Inspect the weldWhile holding pressure, check the flange-to-pipe weld all the way round for leaks or sweating.
  8. Release & removeRelease all pressure and remove the port plugs to drain. Loosen the hex nut so the seal relaxes, remove the bolts and withdraw the plug.

Sizes & part numbers

Find your size.

Choose your flange size and ANSI class: the matching part number, seal clearance, maximum test pressure, installation torque (normal – maximum) and hex nut wrench size are highlighted. Other sizes and ratings on request.

P/N Size ANSI class Seal clearance Max. test pressure Torque (normal – max.) Hex nut wrench
640001 6″DN150 150 0.5″12.7 mm 450 psi31 bar 35–80 ft·lb47.5–108.5 N·m 3/4″
640002 6″DN150 300 0.5″12.7 mm 1,125 psi77.6 bar 45–80 ft·lb61.0–108.5 N·m 3/4″
640003 6″DN150 600 0.5″12.7 mm 2,250 psi155 bar 50–80 ft·lb67.8–108.5 N·m 3/4″
640004 8″DN200 150 0.5″12.7 mm 450 psi31 bar 60–155 ft·lb81.3–210.2 N·m 1 1/16″
640005 8″DN200 300 0.5″12.7 mm 1,125 psi77.6 bar 70–155 ft·lb94.9–210.2 N·m 1 1/16″
640006 8″DN200 600 0.5″12.7 mm 2,250 psi155 bar 80–155 ft·lb108.5–210.2 N·m 1 1/16″
640007 10″DN250 150 0.5″12.7 mm 450 psi31 bar 150–600 ft·lb203.4–813.5 N·m 1 5/8″
640008 10″DN250 300 0.5″12.7 mm 1,125 psi77.6 bar 200–600 ft·lb271.2–813.5 N·m 1 5/8″
640009 10″DN250 600 0.5″12.7 mm 2,250 psi155 bar 300–600 ft·lb406.8–813.5 N·m 1 5/8″
640010 12″DN300 150 0.5″12.7 mm 450 psi31 bar 150–600 ft·lb203.4–813.5 N·m 1 5/8″
640011 12″DN300 300 0.5″12.7 mm 1,125 psi77.6 bar 250–600 ft·lb339.0–813.5 N·m 1 5/8″
640012 12″DN300 600 0.5″12.7 mm 2,250 psi155 bar 300–600 ft·lb406.8–813.5 N·m 1 5/8″
640013 14″DN350 150 0.5″12.7 mm 450 psi31 bar 200–600 ft·lb271.2–813.5 N·m 1 5/8″
640014 14″DN350 300 0.5″12.7 mm 1,125 psi77.6 bar 300–600 ft·lb406.8–813.5 N·m 1 5/8″
640015 14″DN350 600 0.5″12.7 mm 2,250 psi155 bar 300–600 ft·lb406.8–813.5 N·m 1 5/8″
640016 16″DN400 150 0.5″12.7 mm 450 psi31 bar 200–600 ft·lb271.2–813.5 N·m 1 5/8″
640017 16″DN400 300 0.5″12.7 mm 1,125 psi77.6 bar 300–600 ft·lb406.8–813.5 N·m 1 5/8″
640018 16″DN400 600 0.5″12.7 mm 2,250 psi155 bar 300–600 ft·lb406.8–813.5 N·m 1 5/8″
640019 18″DN450 150 0.5″12.7 mm 450 psi31 bar 250–600 ft·lb339.0–813.5 N·m 1 5/8″
640020 18″DN450 300 0.5″12.7 mm 1,125 psi77.6 bar 350–600 ft·lb474.5–813.5 N·m 1 5/8″
640021 18″DN450 600 0.5″12.7 mm 2,250 psi155 bar 350–600 ft·lb474.5–813.5 N·m 1 5/8″
640022 20″DN500 150 0.5″12.7 mm 450 psi31 bar 250–600 ft·lb339.0–813.5 N·m 1 5/8″
640023 20″DN500 300 0.5″12.7 mm 1,125 psi77.6 bar 350–600 ft·lb474.5–813.5 N·m 1 5/8″
640024 20″DN500 600 0.5″12.7 mm 2,250 psi155 bar 350–600 ft·lb474.5–813.5 N·m 1 5/8″
640025 24″DN600 150 0.5″12.7 mm 450 psi31 bar 300–600 ft·lb406.8–813.5 N·m 1 5/8″
640026 24″DN600 300 0.5″12.7 mm 1,125 psi77.6 bar 400–600 ft·lb542.3–813.5 N·m 1 5/8″
640027 24″DN600 600 0.5″12.7 mm 2,250 psi155 bar 400–600 ft·lb542.3–813.5 N·m 1 5/8″

Never exceed the test pressure for the flange class, and never adjust the plug while it is under pressure. Use water and remove all air; keep everyone clear of the plug during the test. When welding, monitor the upstream pressure and stop at once if it rises; the pipe at the seal must never get too hot to touch. Do not let the weld protrude into the bore by more than the seal clearance, or the bore may need grinding before the plug comes out. Vent upstream vapours through about 50 ft (15 m) of hose, ending downwind of the weld.

Applications

Where it works.

Flange-to-pipe weld isolation and testing
Oil, gas and power pipelines
Pipeline fabrication shops
Maintenance and repair work

My project 0

Need a different size or pressure rating?

Send us the pipe I.D., material and test pressure. We will confirm the right plug and lead time.

Request a quote →