DB-WELD™ Double Block Weld Tester

Double block isolation and weld test plug. Two seals isolate the weld from inside the pipe, so you can watch for vapours during hot work and then hydrotest the new weld at up to 2,250 psig (155 barg) with less than 1 gallon (3.8 L) of water. Upstream pressure up to 10 psig (0.7 barg). Size range 0.75″ – 48″ (DN20 – DN1200); standard part numbers 0.75″ – 24″ by pipe schedule.

Additional information

Size range

0.75″ – 48″ (DN20 – DN1200); standard P/N 0.75″ – 24″

Test pressure between seals

2,250 psig (155 barg)

Upstream pressure

Up to 10 psig (0.7 barg); higher on request

Seals

Urethane, rated to 180 °F (82 °C); other compounds on request

Body

Carbon or stainless steel; zinc-plated, polished or custom-coated

Standard

ASME PCC-2 (Article 503) Type IV test device

Part numbers

650002 – 650182

Size range0.75″ – 48″DN20 – DN1200
Test pressure between seals2,250 psig155 barg
Upstream pressure10 psig0.7 barg · higher on request
Seal temperatureUp to 180 °F82 °C · urethane seals
StandardASME PCC-2Type IV test device

DB-WELD™ seals the pipe on both sides of a weld with two seals. The small zone between them is the isolation and test zone, with its own fill and upstream-monitor ports, so you never fill or drain the whole line.

Fit it upstream of the hot-work area to isolate the line and monitor for explosive vapours while you weld. Water or another medium can be circulated between the seals to keep them cool. When the weld has cooled, move the tester so the seals straddle the weld and hydrotest it at up to 2,250 psig (155 barg).

The body is carbon or stainless steel, zinc-plated, polished or custom-coated. A test takes about 10 minutes from insertion to removal, and the plug has extra clearance (up to ⅜″ on larger sizes) for slight weld intrusion.

Key features

  • Two seals: positive pressure barrier around the weld
  • Test pressure between the seals up to 2,250 psig (155 barg)
  • Upstream pressure up to 10 psig (0.7 barg); higher on request
  • Fill port and upstream-monitor port for vapour monitoring during hot work
  • Circulate water between the seals for cooling
  • Less than 1 gallon (3.8 L) of water per test; a hand pump is enough
  • Clearance for slight weld intrusion (up to 3/8″ on larger sizes)
  • Carbon or stainless steel body; zinc-plated, polished or custom-coated
  • ASME PCC-2 (Article 503) Type IV test device
  • Urethane seals as standard; other compounds on request

How to use

Seven steps, one weld.

  1. Know the toolTwo seals block the pipe on both sides of the weld. Only the small test zone between them is filled and pressurised.
  2. Position over the weldSlide the tester into the pipe until the weld sits centred between the two seals. For isolation during hot work, fit it about 12″ (305 mm) upstream of the weld.
  3. Expand the sealsTighten the hex nuts with a calibrated torque wrench, in a star pattern, to the normal torque in the table (never above the maximum). Both seals expand and grip the pipe wall.
  4. Fill & ventConnect water to the fill port and open the vent. The test zone fills and pushes the air out; close the vent when water comes through.
  5. Pressurise & holdFit the gauge on the fill line. Raise slowly to the required test pressure and hold it for the test time. For a pressure-drop test, hold with the pump for at least 5 minutes before you close the valve.
  6. Inspect the weldWhile holding pressure, check the outside of the weld all the way round for leaks or sweating.
  7. Release & removeRelease the pressure to zero, open the vent and drain. Loosen the nuts in steps so the seals relax fully, then pull the tester out.

Sizes & part numbers

Find your size.

Choose your pipe size and schedule: the matching part number, plug OD, distance between seals, length, test pressure and installation torque (normal – maximum) are highlighted. Other sizes (up to 48″) and seal compounds on request.

P/N Size Schedule Plug OD Between seals Length Max. test pressure Torque (normal – max.) NPT ports
650006 0.75″DN20 80 0.65″16.5 mm 1.50″38 mm 22 5/8″575 mm 2,250 psi155 bar 2.5–5.0 ft·lb3.4–6.8 N·m 1/4″
650003 0.75″DN20 10 0.78″19.8 mm 1.50″38 mm 22 5/8″575 mm 2,250 psi155 bar 4.0–7.0 ft·lb5.4–9.5 N·m 1/4″
650007 0.75″DN20 160 0.54″13.7 mm 1.25″32 mm 21.25″540 mm 2,250 psi155 bar 1.5–3.0 ft·lb2.0–4.1 N·m 1/4″
650005 0.75″DN20 40 0.72″18.3 mm 1.50″38 mm 22 5/8″575 mm 2,250 psi155 bar 3.5–6.5 ft·lb4.7–8.8 N·m 1/4″
650015 1″DN25 XXS 0.54″13.7 mm 1.25″32 mm 21.25″540 mm 2,250 psi155 bar 1.5–3.0 ft·lb2.0–4.1 N·m 1/4″
650014 1″DN25 160 0.72″18.3 mm 1.50″38 mm 22 5/8″575 mm 2,250 psi155 bar 3.5–6.5 ft·lb4.7–8.8 N·m 1/4″
650013 1″DN25 80 0.84″21.3 mm 1.50″38 mm 22 5/8″575 mm 2,250 psi155 bar 4.0–7.0 ft·lb5.4–9.5 N·m 1/4″
650012 1″DN25 40 0.93″23.6 mm 1.50″38 mm 22 5/8″575 mm 2,250 psi155 bar 5.0–7.0 ft·lb6.8–9.5 N·m 1/4″
650010 1″DN25 10 0.98″24.9 mm 1.50″38 mm 22 5/8″575 mm 2,250 psi155 bar 5.0–7.5 ft·lb6.8–10.2 N·m 1/4″
650021 1.25″DN32 160 1.01″25.7 mm 1.50″38 mm 23 7/8″606 mm 2,250 psi155 bar 8.0–12 ft·lb10.8–16.3 N·m 1/4″
650020 1.25″DN32 80 1.13″28.7 mm 1.50″38 mm 23 7/8″606 mm 2,250 psi155 bar 10–13 ft·lb13.6–17.6 N·m 1/4″
650019 1.25″DN32 40 1.23″31.2 mm 1.50″38 mm 23 7/8″606 mm 2,250 psi155 bar 11–14 ft·lb14.9–19.0 N·m 1/4″
650017 1.25″DN32 10 1.29″32.8 mm 1.50″38 mm 23 7/8″606 mm 2,250 psi155 bar 12–14 ft·lb16.3–19.0 N·m 1/4″
650028 1.5″DN40 160 1.19″30.2 mm 2.50″64 mm 26.75″679 mm 2,250 psi155 bar 15–20 ft·lb20–27 N·m 1/4″
650027 1.5″DN40 80 1.35″34.3 mm 2.50″64 mm 26.75″679 mm 2,250 psi155 bar 15–20 ft·lb20–27 N·m 1/4″
650026 1.5″DN40 40 1.46″37.1 mm 2.50″64 mm 26.75″679 mm 2,250 psi155 bar 15–20 ft·lb20–27 N·m 1/4″
650024 1.5″DN40 10 1.53″38.9 mm 2.50″64 mm 26.75″679 mm 2,250 psi155 bar 20–30 ft·lb27–41 N·m 1/4″
650036 2″DN50 XXS 1.35″34.3 mm 2.50″64 mm 26.75″679 mm 2,250 psi155 bar 15–20 ft·lb20–27 N·m 1/4″
650035 2″DN50 160 1.53″38.9 mm 2.50″64 mm 26.75″679 mm 2,250 psi155 bar 20–30 ft·lb27–41 N·m 1/4″
650034 2″DN50 80 1.76″44.7 mm 2.50″64 mm 28.5″724 mm 2,250 psi155 bar 30–50 ft·lb41–68 N·m 1/4″
650033 2″DN50 40 1.89″48.0 mm 2.50″64 mm 28.5″724 mm 2,250 psi155 bar 30–50 ft·lb41–68 N·m 1/4″
650031 2″DN50 10 1.98″50.3 mm 2.50″64 mm 29.25″743 mm 2,250 psi155 bar 35–60 ft·lb47–81 N·m 1/4″
650042 2.5″DN65 160 1.95″49.5 mm 2.50″64 mm 28.5″724 mm 2,250 psi155 bar 35–60 ft·lb47–81 N·m 1/4″
650041 2.5″DN65 80 2.13″54.1 mm 2.50″64 mm 29.25″743 mm 2,250 psi155 bar 60–90 ft·lb81–122 N·m 1/4″
650040 2.5″DN65 40 2.29″58.2 mm 2.50″64 mm 29.25″743 mm 2,250 psi155 bar 60–90 ft·lb81–122 N·m 1/4″
650038 2.5″DN65 10 2.46″62.5 mm 2.50″64 mm 34.25″870 mm 2,250 psi155 bar 100–150 ft·lb136–203 N·m 1/4″
650050 3″DN80 XXS 2.13″54.1 mm 2.50″64 mm 29.25″743 mm 2,250 psi155 bar 60–90 ft·lb81–122 N·m 1/4″
650049 3″DN80 160 2.46″62.5 mm 2.50″64 mm 34.25″870 mm 2,250 psi155 bar 100–150 ft·lb136–203 N·m 1/4″
650048 3″DN80 80 2.69″68.3 mm 2.50″64 mm 34.25″870 mm 2,250 psi155 bar 150–200 ft·lb203–271 N·m 1/4″
650047 3″DN80 40 2.86″72.6 mm 2.50″64 mm 34.25″870 mm 2,250 psi155 bar 150–200 ft·lb203–271 N·m 1/4″
650045 3″DN80 10 3.04″77.2 mm 2.50″64 mm 34.25″870 mm 2,250 psi155 bar 175–250 ft·lb237–339 N·m 1/4″
650063 4″DN100 XXS 3.00″76.2 mm 3.5″89 mm 6.5″165 mm 2,250 psi155 bar 10–15 ft·lb14–20 N·m 1/8″upstream 1/8″
650062 4″DN100 160 3.29″83.6 mm 3.5″89 mm 6.5″165 mm 2,250 psi155 bar 15–25 ft·lb20–34 N·m 1/8″upstream 1/8″
650061 4″DN100 120 3.48″88.4 mm 3.5″89 mm 6.5″165 mm 2,250 psi155 bar 20–30 ft·lb27–41 N·m 1/8″upstream 1/8″
650060 4″DN100 80 3.63″92.2 mm 3.5″89 mm 6.5″165 mm 2,250 psi155 bar 20–30 ft·lb27–41 N·m 1/8″upstream 1/8″
650059 4″DN100 40 3.83″97.3 mm 3.5″89 mm 6.5″165 mm 2,250 psi155 bar 20–30 ft·lb27–41 N·m 1/8″upstream 1/8″
650057 4″DN100 10 4.06″103 mm 3.5″89 mm 6.5″165 mm 2,250 psi155 bar 20–30 ft·lb27–41 N·m 1/8″upstream 1/8″
650056 4″DN100 5/5S 4.13″105 mm 3.5″89 mm 6.5″165 mm 2,250 psi155 bar 20–30 ft·lb27–41 N·m 1/8″upstream 1/8″
650077 6″DN150 XXS 4.70″119 mm 4″102 mm 9″229 mm 2,250 psi155 bar 70–110 ft·lb95–149 N·m 1/4″upstream 1/4″
650076 6″DN150 160 4.99″127 mm 4″102 mm 9″229 mm 2,250 psi155 bar 70–110 ft·lb95–149 N·m 1/4″upstream 1/4″
650075 6″DN150 120 5.30″135 mm 4″102 mm 9″229 mm 2,250 psi155 bar 80–120 ft·lb108–163 N·m 1/4″upstream 1/4″
650074 6″DN150 80 5.56″141 mm 4″102 mm 9″229 mm 2,250 psi155 bar 80–130 ft·lb108–176 N·m 1/4″upstream 1/4″
650073 6″DN150 40 5.87″149 mm 4″102 mm 9″229 mm 2,250 psi155 bar 90–140 ft·lb122–190 N·m 1/4″upstream 1/4″
650072 6″DN150 10 6.16″157 mm 4″102 mm 9″229 mm 2,250 psi155 bar 90–140 ft·lb122–190 N·m 1/4″upstream 1/4″
650071 6″DN150 5/5S 6.21″158 mm 4″102 mm 9″229 mm 2,250 psi155 bar 90–140 ft·lb122–190 N·m 1/4″upstream 1/4″
650083 8″DN200 160 6.56″167 mm 4″102 mm 9.5″241 mm 2,250 psi155 bar 125–200 ft·lb169–271 N·m 1/4″upstream 1/4″
650084 8″DN200 XXS 6.63″168 mm 4″102 mm 9.5″241 mm 2,250 psi155 bar 125–200 ft·lb169–271 N·m 1/4″upstream 1/4″
650174 8″DN200 140 6.75″171 mm 4″102 mm 9.5″241 mm 2,250 psi155 bar 125–200 ft·lb169–271 N·m 1/4″upstream 1/4″
650082 8″DN200 120 6.94″176 mm 4″102 mm 9.5″241 mm 2,250 psi155 bar 125–200 ft·lb169–271 N·m 1/4″upstream 1/4″
650175 8″DN200 100 7.19″183 mm 4″102 mm 9.5″241 mm 2,250 psi155 bar 125–200 ft·lb169–271 N·m 1/4″upstream 1/4″
650081 8″DN200 80/XS/80S 7.38″187 mm 4″102 mm 9.5″241 mm 2,250 psi155 bar 150–225 ft·lb203–305 N·m 1/4″upstream 1/4″
650176 8″DN200 60 7.56″192 mm 4″102 mm 9.5″241 mm 2,250 psi155 bar 175–250 ft·lb237–339 N·m 1/4″upstream 1/4″
650080 8″DN200 40/STD/40S 7.73″196 mm 4″102 mm 9.5″241 mm 2,250 psi155 bar 175–250 ft·lb237–339 N·m 1/4″upstream 1/4″
650177 8″DN200 30 7.82″198 mm 4″102 mm 9.5″241 mm 2,250 psi155 bar 175–250 ft·lb237–339 N·m 1/4″upstream 1/4″
650178 8″DN200 20 7.88″200 mm 4″102 mm 9.5″241 mm 2,250 psi155 bar 175–250 ft·lb237–339 N·m 1/4″upstream 1/4″
650079 8″DN200 10/10S 8.08″205 mm 4″102 mm 9.5″241 mm 2,250 psi155 bar 175–250 ft·lb237–339 N·m 1/4″upstream 1/4″
650078 8″DN200 5/5S 8.16″207 mm 4″102 mm 9.5″241 mm 2,250 psi155 bar 175–250 ft·lb237–339 N·m 1/4″upstream 1/4″
650094 10″DN250 160 8.25″210 mm 4″102 mm 9.5″241 mm 2,250 psi155 bar 225–300 ft·lb305–407 N·m 1/4″upstream 1/4″
650095 10″DN250 140/XXS 8.50″216 mm 4″102 mm 9.5″241 mm 2,250 psi155 bar 200–275 ft·lb271–373 N·m 1/4″upstream 1/4″
650093 10″DN250 120 8.81″224 mm 4″102 mm 9.5″241 mm 2,250 psi155 bar 200–275 ft·lb271–373 N·m 1/4″upstream 1/4″
650092 10″DN250 100 9.06″230 mm 4″102 mm 9.5″241 mm 2,250 psi155 bar 200–275 ft·lb271–373 N·m 1/4″upstream 1″
650091 10″DN250 80 9.31″236 mm 4″102 mm 9.5″241 mm 2,250 psi155 bar 200–275 ft·lb271–373 N·m 1/4″upstream 1″
650090 10″DN250 60/XS/80S 9.50″241 mm 4″102 mm 9.5″241 mm 2,250 psi155 bar 200–275 ft·lb271–373 N·m 1/4″upstream 1″
650089 10″DN250 40/STD/40S 9.77″248 mm 4″102 mm 9.5″241 mm 2,250 psi155 bar 225–300 ft·lb305–407 N·m 1/4″upstream 1″
650088 10″DN250 30 9.89″251 mm 4″102 mm 9.5″241 mm 2,250 psi155 bar 225–300 ft·lb305–407 N·m 1/4″upstream 1″
650087 10″DN250 20 10.00″254 mm 4″102 mm 9.5″241 mm 2,250 psi155 bar 225–300 ft·lb305–407 N·m 1/4″upstream 1″
650086 10″DN250 10/10S 10.17″258 mm 4″102 mm 9.5″241 mm 2,250 psi155 bar 225–300 ft·lb305–407 N·m 1/4″upstream 1″
650085 10″DN250 5/5S 10.23″260 mm 4″102 mm 9.5″241 mm 2,250 psi155 bar 225–300 ft·lb305–407 N·m 1/4″upstream 1″
650106 12″DN300 160 9.75″248 mm 4″102 mm 9.5″241 mm 2,250 psi155 bar 225–275 ft·lb305–373 N·m 1/4″upstream 1″
650105 12″DN300 140 10.12″257 mm 4″102 mm 9.5″241 mm 2,250 psi155 bar 225–300 ft·lb305–407 N·m 1/4″upstream 1″
650104 12″DN300 120/XXS 10.37″263 mm 4″102 mm 9.5″241 mm 2,250 psi155 bar 225–300 ft·lb305–407 N·m 1/4″upstream 1″
650103 12″DN300 100 10.69″272 mm 4″102 mm 9.5″241 mm 2,250 psi155 bar 200–250 ft·lb271–339 N·m 1/4″upstream 1″
650102 12″DN300 80 11.00″279 mm 4″102 mm 9.5″241 mm 2,250 psi155 bar 200–250 ft·lb271–339 N·m 1/4″upstream 1″
650101 12″DN300 60 11.25″286 mm 4″102 mm 9.5″241 mm 2,250 psi155 bar 225–275 ft·lb305–373 N·m 1/4″upstream 1″
650099 12″DN300 XS/40/80S 11.37″289 mm 4″102 mm 9.5″241 mm 2,250 psi155 bar 225–275 ft·lb305–373 N·m 1/4″upstream 1″
650179 12″DN300 STD 11.62″295 mm 4″102 mm 9.5″241 mm 2,250 psi155 bar 225–275 ft·lb305–373 N·m 1/4″upstream 1″
650098 12″DN300 30 11.71″297 mm 4″102 mm 9.5″241 mm 2,250 psi155 bar 225–275 ft·lb305–373 N·m 1/4″upstream 1″
650097 12″DN300 20 11.88″302 mm 4″102 mm 9.5″241 mm 2,250 psi155 bar 225–275 ft·lb305–373 N·m 1/4″upstream 1″
650096 12″DN300 5S/10S/10 12.02″305 mm 4″102 mm 9.5″241 mm 2,250 psi155 bar 225–275 ft·lb305–373 N·m 1/4″upstream 1″
650119 14″DN350 160 10.81″275 mm 4″102 mm 9.5″241 mm 2,250 psi155 bar 200–250 ft·lb271–339 N·m 1/4″upstream 1″
650118 14″DN350 140 11.12″282 mm 4″102 mm 9.5″241 mm 2,250 psi155 bar 225–275 ft·lb305–373 N·m 1/4″upstream 1″
650117 14″DN350 120 11.44″291 mm 4″102 mm 9.5″241 mm 2,250 psi155 bar 225–300 ft·lb305–407 N·m 1/4″upstream 1″
650116 14″DN350 100 11.75″299 mm 5.5″140 mm 11″279 mm 2,250 psi155 bar 275–325 ft·lb373–441 N·m 1/4″upstream 1″
650115 14″DN350 80 12.12″308 mm 5.5″140 mm 11″279 mm 2,250 psi155 bar 225–275 ft·lb305–373 N·m 1/4″upstream 2″
650114 14″DN350 60 12.43″316 mm 5.5″140 mm 11″279 mm 2,250 psi155 bar 225–275 ft·lb305–373 N·m 1/4″upstream 2″
650113 14″DN350 XS/80S 12.62″321 mm 5.5″140 mm 11″279 mm 2,250 psi155 bar 225–275 ft·lb305–373 N·m 1/4″upstream 2″
650112 14″DN350 40 12.74″324 mm 5.5″140 mm 11″279 mm 2,250 psi155 bar 225–275 ft·lb305–373 N·m 1/4″upstream 2″
650111 14″DN350 30/STD/40S 12.87″327 mm 5.5″140 mm 11″279 mm 2,250 psi155 bar 225–275 ft·lb305–373 N·m 1/4″upstream 2″
650110 14″DN350 20 13.00″330 mm 5.5″140 mm 11″279 mm 2,250 psi155 bar 225–275 ft·lb305–373 N·m 1/4″upstream 2″
650108 14″DN350 10/10S 13.12″333 mm 5.5″140 mm 11″279 mm 2,250 psi155 bar 225–275 ft·lb305–373 N·m 1/4″upstream 2″
650107 14″DN350 5/5S 13.31″338 mm 5.5″140 mm 11″279 mm 2,250 psi155 bar 250–275 ft·lb339–373 N·m 1/4″upstream 2″
650130 16″DN400 160 12.43″316 mm 5.5″140 mm 11″279 mm 2,250 psi155 bar 225–275 ft·lb305–373 N·m 1/4″upstream 2″
650129 16″DN400 140 12.74″324 mm 5.5″140 mm 11″279 mm 2,250 psi155 bar 225–275 ft·lb305–373 N·m 1/4″upstream 2″
650128 16″DN400 120 13.18″335 mm 5.5″140 mm 11″279 mm 2,250 psi155 bar 225–275 ft·lb305–373 N·m 1/4″upstream 2″
650127 16″DN400 100 13.56″344 mm 5.5″140 mm 11″279 mm 2,250 psi155 bar 200–250 ft·lb271–339 N·m 1/4″upstream 2″
650126 16″DN400 80 13.93″354 mm 5.5″140 mm 11″279 mm 2,250 psi155 bar 200–250 ft·lb271–339 N·m 1/4″upstream 2″
650125 16″DN400 60 14.31″364 mm 5.5″140 mm 11″279 mm 2,250 psi155 bar 225–275 ft·lb305–373 N·m 1/4″upstream 2″
650124 16″DN400 40/XS/80S 14.62″371 mm 5.5″140 mm 11″279 mm 2,250 psi155 bar 225–275 ft·lb305–373 N·m 1/4″upstream 2″
650123 16″DN400 30/STD/40S 14.87″378 mm 5.5″140 mm 11″279 mm 2,250 psi155 bar 250–300 ft·lb339–407 N·m 1/4″upstream 2″
650122 16″DN400 20 15.00″381 mm 5.5″140 mm 11″279 mm 2,250 psi155 bar 250–300 ft·lb339–407 N·m 1/4″upstream 2″
650121 16″DN400 10 15.12″384 mm 5.5″140 mm 11″279 mm 2,250 psi155 bar 250–300 ft·lb339–407 N·m 1/4″upstream 2″
650120 16″DN400 5/5S 15.29″388 mm 5.5″140 mm 11″279 mm 2,250 psi155 bar 250–300 ft·lb339–407 N·m 1/4″upstream 2″
650143 18″DN450 160 14.06″357 mm 5.5″140 mm 11″279 mm 2,250 psi155 bar 225–275 ft·lb305–373 N·m 1/4″upstream 2″
650142 18″DN450 140 14.50″368 mm 5.5″140 mm 11″279 mm 2,250 psi155 bar 225–275 ft·lb305–373 N·m 1/4″upstream 2″
650141 18″DN450 120 14.87″378 mm 5.5″140 mm 11″279 mm 2,250 psi155 bar 250–300 ft·lb339–407 N·m 1/4″upstream 2″
650140 18″DN450 100 15.31″389 mm 5.5″140 mm 11″279 mm 2,250 psi155 bar 250–300 ft·lb339–407 N·m 1/4″upstream 2″
650139 18″DN450 80 15.74″400 mm 5.5″140 mm 11″279 mm 2,250 psi155 bar 250–300 ft·lb339–407 N·m 1/4″upstream 2″
650138 18″DN450 60 16.12″409 mm 5.5″140 mm 11″279 mm 2,250 psi155 bar 250–300 ft·lb339–407 N·m 1/4″upstream 2″
650137 18″DN450 40 16.50″419 mm 5.5″140 mm 11″279 mm 2,250 psi155 bar 250–300 ft·lb339–407 N·m 1/4″upstream 2″
650136 18″DN450 XS 16.62″422 mm 5.5″140 mm 11″279 mm 2,250 psi155 bar 275–325 ft·lb373–441 N·m 1/4″upstream 2″
650135 18″DN450 30 16.74″425 mm 5.5″140 mm 11″279 mm 2,250 psi155 bar 275–325 ft·lb373–441 N·m 1/4″upstream 2″
650134 18″DN450 STD 16.87″428 mm 5.5″140 mm 11″279 mm 2,250 psi155 bar 275–325 ft·lb373–441 N·m 1/4″upstream 2″
650133 18″DN450 20 17.00″432 mm 5.5″140 mm 11″279 mm 2,250 psi155 bar 275–325 ft·lb373–441 N·m 1/4″upstream 2″
650131 18″DN450 10/10S/5 17.24″438 mm 5.5″140 mm 11″279 mm 2,250 psi155 bar 275–325 ft·lb373–441 N·m 1/4″upstream 2″
650153 20″DN500 160 15.68″398 mm 5.5″140 mm 11.5″292 mm 2,250 psi155 bar 250–300 ft·lb339–407 N·m 1/4″upstream 2″
650152 20″DN500 140 16.12″409 mm 5.5″140 mm 11.5″292 mm 2,250 psi155 bar 250–300 ft·lb339–407 N·m 1/4″upstream 2″
650151 20″DN500 120 16.62″422 mm 5.5″140 mm 11.5″292 mm 2,250 psi155 bar 250–300 ft·lb339–407 N·m 1/4″upstream 2″
650150 20″DN500 100 17.06″433 mm 5.5″140 mm 11.5″292 mm 2,250 psi155 bar 275–325 ft·lb373–441 N·m 1/4″upstream 2″
650149 20″DN500 80 17.56″446 mm 5.5″140 mm 11.5″292 mm 2,250 psi155 bar 225–275 ft·lb305–373 N·m 1/4″upstream 2″
650148 20″DN500 60 18.00″457 mm 5.5″140 mm 11.5″292 mm 2,250 psi155 bar 195–280 ft·lb264–380 N·m 1/4″upstream 2″
650147 20″DN500 40 18.43″468 mm 5.5″140 mm 11.5″292 mm 2,250 psi155 bar 175–225 ft·lb237–305 N·m 1/4″upstream 2″
650146 20″DN500 30/XS 18.62″473 mm 5.5″140 mm 11.5″292 mm 2,250 psi155 bar 225–275 ft·lb305–373 N·m 1/4″upstream 2″
650145 20″DN500 20/STD 18.87″479 mm 5.5″140 mm 11.5″292 mm 2,250 psi155 bar 225–275 ft·lb305–373 N·m 1/4″upstream 2″
650144 20″DN500 10 19.12″486 mm 5.5″140 mm 11.5″292 mm 2,250 psi155 bar 250–325 ft·lb339–441 N·m 1/4″upstream 2″
650180 20″DN500 5 19.25″489 mm 5.5″140 mm 11.5″292 mm 2,250 psi155 bar 250–325 ft·lb339–441 N·m 1/4″upstream 2″
650162 22″DN550 160 17.37″441 mm 5.5″140 mm 11.5″292 mm 2,250 psi155 bar 225–275 ft·lb305–373 N·m 1/4″upstream 2″
650161 22″DN550 140 17.87″454 mm 5.5″140 mm 11.5″292 mm 2,250 psi155 bar 225–275 ft·lb305–373 N·m 1/4″upstream 2″
650160 22″DN550 120 18.37″467 mm 5.5″140 mm 11.5″292 mm 2,250 psi155 bar 225–275 ft·lb305–373 N·m 1/4″upstream 2″
650159 22″DN550 100 18.87″479 mm 5.5″140 mm 11.5″292 mm 2,250 psi155 bar 225–275 ft·lb305–373 N·m 1/4″upstream 2″
650158 22″DN550 80 19.37″492 mm 5.5″140 mm 11.5″292 mm 2,250 psi155 bar 275–325 ft·lb373–441 N·m 1/4″upstream 2″
650157 22″DN550 60 19.87″505 mm 5.5″140 mm 11.5″292 mm 2,250 psi155 bar 250–300 ft·lb339–407 N·m 1/4″upstream 2″
650156 22″DN550 30/XS 20.62″524 mm 5.5″140 mm 11.5″292 mm 2,250 psi155 bar 250–300 ft·lb339–407 N·m 1/4″upstream 2″
650155 22″DN550 20/STD 20.87″530 mm 5.5″140 mm 11.5″292 mm 2,250 psi155 bar 250–300 ft·lb339–407 N·m 1/4″upstream 2″
650154 22″DN550 10/10S 21.18″538 mm 5.5″140 mm 11.5″292 mm 2,250 psi155 bar 275–325 ft·lb373–441 N·m 1/4″upstream 2″
650181 22″DN550 5 21.25″540 mm 5.5″140 mm 11.5″292 mm 2,250 psi155 bar 275–325 ft·lb373–441 N·m 1/4″upstream 2″
650173 24″DN600 160 18.93″481 mm 5.5″140 mm 11.5″292 mm 2,250 psi155 bar 225–275 ft·lb305–373 N·m 1/4″upstream 2″
650172 24″DN600 140 19.50″495 mm 5.5″140 mm 11.5″292 mm 2,250 psi155 bar 250–300 ft·lb339–407 N·m 1/4″upstream 2″
650171 24″DN600 120 20.00″508 mm 5.5″140 mm 11.5″292 mm 2,250 psi155 bar 250–300 ft·lb339–407 N·m 1/4″upstream 2″
650170 24″DN600 100 20.56″522 mm 5.5″140 mm 11.5″292 mm 2,250 psi155 bar 250–300 ft·lb339–407 N·m 1/4″upstream 2″
650169 24″DN600 80 21.18″538 mm 5.5″140 mm 11.5″292 mm 2,250 psi155 bar 275–325 ft·lb373–441 N·m 1/4″upstream 2″
650168 24″DN600 60 21.68″551 mm 5.5″140 mm 11.5″292 mm 2,250 psi155 bar 300–350 ft·lb407–475 N·m 1/4″upstream 2″
650167 24″DN600 40 22.24″565 mm 5.5″140 mm 11.5″292 mm 2,250 psi155 bar 300–350 ft·lb407–475 N·m 1/4″upstream 2″
650166 24″DN600 30 22.50″572 mm 5.5″140 mm 11.5″292 mm 2,250 psi155 bar 275–325 ft·lb373–441 N·m 1/4″upstream 2″
650165 24″DN600 XS 22.62″575 mm 5.5″140 mm 11.5″292 mm 2,250 psi155 bar 275–325 ft·lb373–441 N·m 1/4″upstream 2″
650164 24″DN600 20/STD 22.87″581 mm 5.5″140 mm 11.5″292 mm 2,250 psi155 bar 275–325 ft·lb373–441 N·m 1/4″upstream 2″
650163 24″DN600 10 23.12″587 mm 5.5″140 mm 11.5″292 mm 2,250 psi155 bar 300–350 ft·lb407–475 N·m 1/4″upstream 2″
650182 24″DN600 5 23.18″589 mm 5.5″140 mm 11.5″292 mm 2,250 psi155 bar 300–350 ft·lb407–475 N·m 1/4″upstream 2″

Upstream pressure must not exceed 10 psig (0.7 barg); for live lines use DBG-WELD™. Monitor the upstream pressure all the time the plug is installed. Urethane seals are rated to 180 °F (82 °C): during hot work keep the plug about 12″ (305 mm) from the weld, and test only after the weld has cooled. Use water and remove all air, and keep everyone clear while under pressure. Put anti-seize only on the shaft threads and both sides of the hardened washers, never on the seals or the pipe bore. After the test, back off the nuts so the seals can relax to their original size.

Applications

Where it works.

Flange-to-pipe weld testing and tie-in work
Oil, gas and chemical process plants
Offshore platforms and shipyards
Plant revamps and flange replacement programmes

My project 0

Need a different size or pressure rating?

Send us the pipe I.D., material and test pressure. We will confirm the right plug and lead time.

Request a quote →