BALL-PLUG™ Balloon Pipe Test Plug

Inflatable rubber balloon plug for blocking and low-pressure testing of drain, waste and sewer pipes. Push it into the pipe, inflate it with the hand bulb pump and it seals against the wall; deflate to take it out. Ten sizes from 2″ to 24″ (50 – 600 mm); larger sizes on request.

Additional information

Pipe size

2″ – 24″ (50 – 600 mm)

Working pressure

2.2 – 2.9 psi (0.15 – 0.2 bar)

Water head

Up to 4.9 ft (1.5 m)

Material

Moulded rubber, hand bulb pump

Part numbers

230001 – 230010

Pipe size2″ – 24″50 – 600 mm · 10 sizes
Working pressure2.2 – 2.9 psi0.15 – 0.2 bar
Water headup to 4.9 ft1.5 m blocking depth
BodyThick moulded rubberintegrated carry handles
InflationHand bulb pumphose with release valve

BALL-PLUG™ is a one-piece balloon plug for plumbers and drainage crews. Slide it into the pipe or fitting, squeeze the hand bulb and the thick rubber body expands to fill the bore and hold back the water. It works in straight pipe ends, tee branches, bends and floor drains.

The body is moulded in one piece from thickened rubber with integrated handles, so it is easy to carry, place and pull out again. Each model covers its own pipe size; pick the size from the table and never inflate the plug outside a pipe.

Key features

  • Inflates by hand: bulb pump and hose, no compressor needed
  • One-piece moulded rubber body, thickened for strength
  • Expands to fill the bore and block the water
  • Holds back up to 1.5 m (4.9 ft) of water
  • Integrated handles to carry, place and remove
  • Works in pipe ends, tees, bends and floor drains
  • Ten sizes 2″ – 24″ (50 – 600 mm); larger on request

How to use

Six steps, one plug.

BALL-PLUG installation: pipe end, tee branch, bend and floor drain
  1. Choose the sizeMeasure the pipe and pick the model that matches it in the table.
  2. Check the pipeClean the inside of the pipe and remove sharp edges, burrs or debris that could cut the rubber.
  3. Insert the plugPush the deflated plug fully into the pipe or fitting, with the valve and hose towards you.
  4. InflateSqueeze the hand bulb until the plug seals firmly against the pipe wall. Do not over-inflate.
  5. Block or testCarry out the work or the low-pressure test. Keep the water head within 1.5 m (4.9 ft).
  6. Deflate & removeOpen the release valve, let the plug deflate fully, then pull it out by the handles.

Sizes & part numbers

Find your size.

Enter your pipe inner diameter to highlight the matching model. Larger sizes are made to order.

P/N Pipe size Length Working pressure Weight
230001 2″ · 50 mm 4.7″120 mm 2.2–2.9 psi0.15–0.2 bar 0.10 kg
230002 3″ · 75 mm 5.1″130 mm 2.2–2.9 psi0.15–0.2 bar 0.16 kg
230003 4″ · 100–110 mm 5.9″150 mm 2.2–2.9 psi0.15–0.2 bar 0.30 kg
230004 6″ · 150–160 mm 7.5″190 mm 2.2–2.9 psi0.15–0.2 bar 0.60 kg
230005 8″ · 200 mm 9.1″230 mm 2.2–2.9 psi0.15–0.2 bar 0.85 kg
230006 9–10″ · 225–250 mm 11″280 mm 2.2–2.9 psi0.15–0.2 bar 1.30 kg
230007 12″ · 300–315 mm 14.6″370 mm 2.2–2.9 psi0.15–0.2 bar 2.10 kg
230008 16″ · 400 mm 17.3″440 mm 2.2–2.9 psi0.15–0.2 bar 3.50 kg
230009 20″ · 500 mm 24″610 mm 2.2–2.9 psi0.15–0.2 bar 5.10 kg
230010 24″ · 600 mm 28″710 mm 2.2–2.9 psi0.15–0.2 bar 8.00 kg

Use the plug only inside a pipe of the matching size; never inflate it in open air. Inflate by hand to the working pressure only, and keep the water head within 1.5 m (4.9 ft). Keep people clear of the pipe end while the plug is under load.

Applications

Where it works.

Plumbing and drainage tests
Blocking pipes during repair and maintenance
Floor drains, gullies and chambers
PVC, UPVC and other drain pipes
Residential and commercial buildings