INFLA-PTEST™ High-Pressure Inflatable Test Plug

High Pressure multi-size inflatable test plug with a bypass, for hydrostatic testing and isolation of water, sewer, drainage, oil and gas lines. 9 sizes for pipe bores from 4″ to 72″ (100 – 1,800 mm), single or double bypass, working pressure 87 psi (6 bar) and back pressure 43.5 psi (3 bar).

Additional information

Pipe I.D. range

4″ – 72″ (100 – 1,800 mm), multi-size

Working pressure

87 psi (6 bar), all models

Back pressure

43.5 psi (3 bar), all models

Bypass

Single or double, 1/4″ to 2 × 2″

Series

TPR-INFLA™

Part numbers

220026 – 220047

Pipe I.D.4″ – 72″100 – 1,800 mm · multi-size
Working pressure87 psi6 bar · all models
Back pressure43.5 psi3 bar · all models
BypassSingle or double1/4″ to 2 × 2″
SeriesTPR-INFLA™high-pressure

INFLA-PTEST™ is a multi-size, high-pressure inflatable test plug with a bypass through its body. It seals the line for hydrostatic testing and isolation, while the bypass lets you fill, vent or drain the line and connect test equipment without removing the plug.

Each model covers a range of bores, so a few plugs handle many pipe sizes on site. Choose a single or double bypass to suit your test set-up. It is used on water, sewer, drainage, oil and gas lines. Always check the rated pressures for your model before you inflate.

Key features

  • Multi-size: each model seals a range of bores
  • Working pressure 87 psi (6 bar) on every model
  • Back pressure up to 43.5 psi (3 bar)
  • Bypass through the plug: single or double, 1/4″ to 2 × 2″
  • For hydrostatic testing and isolation
  • Water, sewer, drainage, oil and gas lines
  • Other sizes on request

How to use

Seven steps, one plug.

  1. Know the plugAn inflatable rubber body seals the pipe; the bypass passes through it for filling, venting or flow.
  2. Confirm the fitMeasure the pipe I.D. and pick the model whose range covers it, with the bypass size you need.
  3. Clean the pipeClean the seal area and remove debris and anything sharp that could cut the rubber.
  4. Insert fullyPush the plug fully inside the pipe, square to the pipe axis, with the bypass towards you.
  5. Inflate with a gaugeInflate slowly with a calibrated gauge, up to the working pressure.
  6. Fill & testConnect the test hose to the bypass, fill and vent the line, then run the test within the back-pressure limit.
  7. Release & removeRelease the line pressure first, deflate the plug fully, then pull it out and inspect it.

Sizes & part numbers

Find your size.

Enter your pipe inner diameter: every model whose range covers it is highlighted. Each size comes with a single or double bypass. Other sizes on request.

P/N Nominal size Min. pipe Ø Max. pipe Ø Working pressure Back pressure Product Ø Product length Bypass Ø Product weight
220026 4–8″100–200 mm 4″100 mm 8″200 mm 87 psi6.0 bar 43.5 psi3.0 bar 3.3″85 mm 19.7″500 mm 1″ 2.1 kg
220036 4–8″100–200 mm 4″100 mm 8″200 mm 87 psi6.0 bar 43.5 psi3.0 bar 3.3″85 mm 19.7″500 mm 2 × 1/2″ 2.3 kg
220027 6–12″150–300 mm 6″150 mm 12″300 mm 87 psi6.0 bar 43.5 psi3.0 bar 5.3″135 mm 19.7″500 mm 2″ 7.2 kg
220037 6–12″150–300 mm 6″150 mm 12″300 mm 87 psi6.0 bar 43.5 psi3.0 bar 5.3″135 mm 19.7″500 mm 1″ + 1/2″ 7.5 kg
220028 8–16″200–400 mm 8″200 mm 16″400 mm 87 psi6.0 bar 43.5 psi3.0 bar 7.2″182 mm 23.6″600 mm 2″ 8.3 kg
220038 8–16″200–400 mm 8″200 mm 16″400 mm 87 psi6.0 bar 43.5 psi3.0 bar 7.2″182 mm 23.6″600 mm 2 × 1″ 8.6 kg
220029 12–24″300–600 mm 12″300 mm 24″600 mm 87 psi6.0 bar 43.5 psi3.0 bar 11″280 mm 31.5″800 mm 2″ 19 kg
220039 12–24″300–600 mm 12″300 mm 24″600 mm 87 psi6.0 bar 43.5 psi3.0 bar 11″280 mm 31.5″800 mm 2 × 2″ 20 kg
220030 16–32″400–800 mm 16″400 mm 32″800 mm 87 psi6.0 bar 43.5 psi3.0 bar 14″355 mm 39.4″1000 mm 2″ 32 kg
220047 16–32″400–800 mm 16″400 mm 32″800 mm 87 psi6.0 bar 43.5 psi3.0 bar 14″355 mm 39.4″1000 mm 2 × 2″ 35 kg
220031 20–40″500–1000 mm 20″500 mm 40″1000 mm 87 psi6.0 bar 43.5 psi3.0 bar 18.9″480 mm 41.3″1050 mm 2″ 38 kg
220040 20–40″500–1000 mm 20″500 mm 40″1000 mm 87 psi6.0 bar 43.5 psi3.0 bar 18.9″480 mm 41.3″1050 mm 2 × 2″ 42 kg
220032 24–48″600–1200 mm 24″600 mm 48″1200 mm 87 psi6.0 bar 43.5 psi3.0 bar 22.8″580 mm 49.2″1250 mm 2″ 65 kg
220041 24–48″600–1200 mm 24″600 mm 48″1200 mm 87 psi6.0 bar 43.5 psi3.0 bar 22.8″580 mm 49.2″1250 mm 2 × 2″ 70 kg
220033 32–64″800–1600 mm 32″800 mm 64″1600 mm 87 psi6.0 bar 43.5 psi3.0 bar 30.7″780 mm 47.2″1200 mm 2″ 90 kg
220042 32–64″800–1600 mm 32″800 mm 64″1600 mm 87 psi6.0 bar 43.5 psi3.0 bar 30.7″780 mm 47.2″1200 mm 2 × 2″ 100 kg
220034 48–72″1200–1800 mm 48″1200 mm 72″1800 mm 87 psi6.0 bar 43.5 psi3.0 bar 46.5″1180 mm 63″1600 mm 2″ 200 kg
220043 48–72″1200–1800 mm 48″1200 mm 72″1800 mm 87 psi6.0 bar 43.5 psi3.0 bar 46.5″1180 mm 63″1600 mm 2 × 2″ 225 kg

Never exceed the working or back pressure, and never inflate the plug outside a pipe. Use a calibrated gauge, anchor the plug before pressurising and never stand in line with it while the line is under pressure. All models: working pressure 87 psi (6 bar), back pressure 43.5 psi (3 bar).

Applications

Where it works.

Hydrostatic pressure testing
Oil and gas lines
Water supply networks
Sewer and drainage lines
Isolation during repair and maintenance