DBG-WELD™ Gripper Double Block Isolation & Weld Test Plug

Double block isolation plug with an internal gripper, for flange and tie-in welds on lines that still carry upstream pressure up to 1,500 psig (103 barg). Isolate and monitor during hot work, then hydrotest the new weld at up to 2,250 psig (155 barg) between the seals. Size range 0.75″ – 48″ (DN20 – DN1200); standard part numbers 0.75″ – 24″ by pipe schedule.

Additional information

Size range

0.75″ – 48″ (DN20 – DN1200); standard P/N 0.75″ – 24″

Test pressure between seals

2,250 psig (155 barg)

Upstream pressure

Up to 1,500 psig (103 barg); higher on request

Temperature

−10 °F to +180 °F (−23 °C to +82 °C)

Body / grippers

Carbon or stainless steel / hardened steel

Standards

ASME PCC-2, B16.5, B31.1, B31.3

Part numbers

660002 – 660178

Size range0.75″ – 48″DN20 – DN1200
Test pressure between seals2,250 psig155 barg
Upstream pressure1,500 psig103 barg · higher on request
Temperature−10 °F to +180 °F−23 °C to +82 °C
StandardsASME PCC-2B16.5 · B31.1 · B31.3

DBG-WELD™ combines a double block plug with a serrated internal gripper. Two seals create a positive pressure barrier around the weld, and the gripper holds the plug against upstream pressure up to 1,500 psig (103 barg), so an unexpected rise in line pressure cannot push it out. The higher the upstream pressure, the harder the gripper bites.

Use it to isolate the hot-work area from residual gases and to monitor them through the upstream port while you weld. Water can be circulated between the seals to cool them. After the weld has cooled below 180 °F (82 °C), position the seals over the weld and hydrotest it at up to 2,250 psig (155 barg), in about 10 minutes from insertion to removal.

Each test needs less than 1 gallon (3.8 L) of water, which cuts fill time and waste-water treatment. The body is carbon or stainless steel with hardened steel grippers, and the plug has extra clearance (up to ⅜″ on larger sizes) for slight weld intrusion.

Key features

  • Double block: two seals with a positive pressure barrier between them
  • Upstream pressure up to 1,500 psig (103 barg); higher on request
  • Test pressure between the seals up to 2,250 psig (155 barg)
  • Serrated hardened-steel gripper: holds tighter as upstream pressure rises
  • Upstream-monitor port for explosive vapours during hot work
  • Circulate water between the seals for cooling
  • Less than 1 gallon (3.8 L) of water per test
  • Clearance for slight weld intrusion (up to 3/8″ on larger sizes)
  • ASME PCC-2 (Article 503) Type IV test device; for B16.5, B31.1 and B31.3 work
  • Urethane seals as standard; neoprene, FKM, silicone, EPDM, NR, NBR or SBR on request

How to use

Eight steps, live line.

  1. Know the toolTwo seals block the pipe on both sides of the weld, and an internal gripper holds the tool. The zone between the seals has a bleed connection.
  2. Confirm the applicationIn-service use needs an engineered isolation plan. Confirm the upstream pressure (up to 1,500 psig / 103 barg), the medium, the site conditions and the approved model.
  3. Position over the weldSlide the tester in, gripper end first, until the weld sits centred between the two seals.
  4. Grip & sealTighten the hex nuts with a calibrated torque wrench, in a star pattern, to the normal torque in the table (never above the maximum). The gripper locks onto the pipe wall and both seals expand.
  5. Fill & bleedConnect water to the fill port and open the bleed. The test zone fills and pushes the air out.
  6. Pressurise & holdFit the gauge on the fill line. Raise slowly to the required test pressure and hold it for the test time, while you keep watching the upstream pressure.
  7. Inspect the weldWhile holding pressure, check the outside of the weld all the way round for leaks or sweating.
  8. Release & removeRelease the pressure to zero, open the bleed and drain. Loosen the nuts in steps so the seals and gripper relax fully, then pull the tester out.

Sizes & part numbers

Find your size.

Choose your pipe size and schedule: the matching part number, plug OD, distance between seals, length, test pressure and installation torque (normal – maximum) are highlighted. Other sizes (up to 48″) and seal compounds on request.

P/N Size Schedule Plug OD Between seals Length Max. test pressure Torque (normal – max.) NPT ports
660007 0.75″DN20 160 0.54″13.7 mm 1.50″38.1 mm 21.5″546 mm 2,250 psi155 bar 1.5–3.0 ft·lb2.0–4.1 N·m 1/4″
660006 0.75″DN20 80 0.65″16.5 mm 1.75″44.5 mm 23.5″597 mm 2,250 psi155 bar 2.5–5.0 ft·lb3.4–6.8 N·m 1/4″
660005 0.75″DN20 40 0.72″18.3 mm 1.75″44.5 mm 23.5″597 mm 2,250 psi155 bar 3.5–6.5 ft·lb4.7–8.8 N·m 1/4″
660003 0.75″DN20 10 0.78″19.8 mm 1.75″44.5 mm 23.5″597 mm 2,250 psi155 bar 4.0–7.0 ft·lb5.4–9.5 N·m 1/4″
660015 1″DN25 XXS 0.54″13.7 mm 1.50″38.1 mm 21.5″546 mm 2,250 psi155 bar 1.5–3.0 ft·lb2.0–4.1 N·m 1/4″
660014 1″DN25 160 0.72″18.3 mm 1.75″44.5 mm 23.5″597 mm 2,250 psi155 bar 3.5–6.5 ft·lb4.7–8.8 N·m 1/4″
660013 1″DN25 80 0.84″21.3 mm 1.75″44.5 mm 23.5″597 mm 2,250 psi155 bar 4.0–7.0 ft·lb5.4–9.5 N·m 1/4″
660012 1″DN25 40 0.93″23.6 mm 1.75″44.5 mm 23.5″597 mm 2,250 psi155 bar 5.0–7.0 ft·lb6.8–9.5 N·m 1/4″
660010 1″DN25 10 0.98″24.9 mm 1.75″44.5 mm 23.5″597 mm 2,250 psi155 bar 5.0–7.5 ft·lb6.8–10.2 N·m 1/4″
660021 1.25″DN32 160 1.04″26.4 mm 1.75″44.5 mm 24.75″629 mm 2,250 psi155 bar 8.0–12 ft·lb10.8–16.3 N·m 1/4″
660020 1.25″DN32 80 1.13″28.7 mm 1.75″44.5 mm 24.75″629 mm 2,250 psi155 bar 10–13 ft·lb13.6–17.6 N·m 1/4″
660019 1.25″DN32 40 1.23″31.2 mm 1.75″44.5 mm 24.75″629 mm 2,250 psi155 bar 11–14 ft·lb14.9–19.0 N·m 1/4″
660017 1.25″DN32 10 1.29″32.8 mm 1.75″44.5 mm 24.75″629 mm 2,250 psi155 bar 12–14 ft·lb16.3–19.0 N·m 1/4″
660022 1.25″DN32 XXS 0.80″20.3 mm 1.75″44.5 mm 24.75″629 mm 2,250 psi155 bar 5.0–7.5 ft·lb6.8–10.2 N·m 1/4″
660028 1.5″DN40 160 1.19″30.2 mm 2.75″69.9 mm 27″686 mm 2,250 psi155 bar 15–20 ft·lb20–27 N·m 1/4″
660027 1.5″DN40 80 1.35″34.3 mm 2.75″69.9 mm 27″686 mm 2,250 psi155 bar 15–20 ft·lb20–27 N·m 1/4″
660026 1.5″DN40 40 1.46″37.1 mm 2.75″69.9 mm 27″686 mm 2,250 psi155 bar 15–20 ft·lb20–27 N·m 1/4″
660024 1.5″DN40 10 1.53″38.9 mm 2.75″69.9 mm 27″686 mm 2,250 psi155 bar 20–30 ft·lb27–41 N·m 1/4″
660036 2″DN50 XXS 1.35″34.3 mm 2.75″69.9 mm 27″686 mm 2,250 psi155 bar 15–20 ft·lb20–27 N·m 1/4″
660035 2″DN50 160 1.53″38.9 mm 2.75″69.9 mm 27″686 mm 2,250 psi155 bar 20–30 ft·lb27–41 N·m 1/4″
660034 2″DN50 80 1.76″44.7 mm 2.75″69.9 mm 28.5″724 mm 2,250 psi155 bar 30–50 ft·lb41–68 N·m 1/4″
660033 2″DN50 40 1.89″48.0 mm 2.75″69.9 mm 28.5″724 mm 2,250 psi155 bar 30–50 ft·lb41–68 N·m 1/4″
660031 2″DN50 10 1.98″50.3 mm 2.75″69.9 mm 28.5″724 mm 2,250 psi155 bar 35–60 ft·lb47–81 N·m 1/4″
660043 2.5″DN65 XXS 1.61″40.9 mm 2.75″69.9 mm 27″686 mm 2,250 psi155 bar 20–30 ft·lb27–41 N·m 1/4″
660042 2.5″DN65 160 1.95″49.5 mm 2.75″69.9 mm 28.5″724 mm 2,250 psi155 bar 35–60 ft·lb47–81 N·m 1/4″
660041 2.5″DN65 80 2.13″54.1 mm 2.75″69.9 mm 29″737 mm 2,250 psi155 bar 60–90 ft·lb81–122 N·m 1/4″
660040 2.5″DN65 40 2.29″58.2 mm 2.75″69.9 mm 29″737 mm 2,250 psi155 bar 60–90 ft·lb81–122 N·m 1/4″
660038 2.5″DN65 10 2.46″62.5 mm 2.75″69.9 mm 33 5/8″854 mm 2,250 psi155 bar 100–150 ft·lb136–203 N·m 1/4″
660050 3″DN80 XXS 2.13″54.1 mm 2.75″69.9 mm 29″737 mm 2,250 psi155 bar 60–90 ft·lb81–122 N·m 1/4″
660049 3″DN80 160 2.46″62.5 mm 2.75″69.9 mm 33 5/8″854 mm 2,250 psi155 bar 100–150 ft·lb136–203 N·m 1/4″
660048 3″DN80 80 2.69″68.3 mm 2.75″69.9 mm 33 5/8″854 mm 2,250 psi155 bar 150–200 ft·lb203–271 N·m 1/4″
660047 3″DN80 40 2.86″72.6 mm 2.75″69.9 mm 33 5/8″854 mm 2,250 psi155 bar 150–200 ft·lb203–271 N·m 1/4″
660045 3″DN80 10 3.04″77.2 mm 2.75″69.9 mm 33 5/8″854 mm 2,250 psi155 bar 175–250 ft·lb237–339 N·m 1/4″
660063 4″DN100 XXS 3.00″76.2 mm 3.5″89 mm 10″254 mm 2,250 psi155 bar 10–15 ft·lb14–20 N·m 1/8″upstream 1/8″
660062 4″DN100 160 3.29″83.6 mm 3.5″89 mm 10″254 mm 2,250 psi155 bar 15–25 ft·lb20–34 N·m 1/8″upstream 1/8″
660061 4″DN100 120 3.48″88.4 mm 3.5″89 mm 10″254 mm 2,250 psi155 bar 20–30 ft·lb27–41 N·m 1/8″upstream 1/8″
660060 4″DN100 80 3.63″92.2 mm 3.5″89 mm 10″254 mm 2,250 psi155 bar 20–30 ft·lb27–41 N·m 1/8″upstream 1/8″
660059 4″DN100 40 3.83″97.3 mm 3.5″89 mm 10″254 mm 2,250 psi155 bar 20–30 ft·lb27–41 N·m 1/8″upstream 1/8″
660057 4″DN100 10S 4.06″103.1 mm 3.5″89 mm 10″254 mm 2,250 psi155 bar 20–30 ft·lb27–41 N·m 1/8″upstream 1/8″
660077 6″DN150 XXS 4.70″119.4 mm 4″102 mm 12 3/8″314 mm 2,250 psi155 bar 70–110 ft·lb95–149 N·m 1/4″upstream 1/4″
660076 6″DN150 160 4.99″126.7 mm 4″102 mm 12 3/8″314 mm 2,250 psi155 bar 70–110 ft·lb95–149 N·m 1/4″upstream 1/4″
660075 6″DN150 120 5.30″134.6 mm 4″102 mm 12 3/8″314 mm 2,250 psi155 bar 80–120 ft·lb109–163 N·m 1/4″upstream 1/4″
660074 6″DN150 80 5.56″141.2 mm 4″102 mm 12 3/8″314 mm 2,250 psi155 bar 80–130 ft·lb109–176 N·m 1/4″upstream 1/4″
660073 6″DN150 40 5.87″149.1 mm 4″102 mm 12 3/8″314 mm 2,250 psi155 bar 90–140 ft·lb122–190 N·m 1/4″upstream 1/4″
660072 6″DN150 10S 6.16″156.5 mm 4″102 mm 12 3/8″314 mm 2,250 psi155 bar 90–140 ft·lb122–190 N·m 1/4″upstream 1/4″
660083 8″DN200 160 6.56″167 mm 5″127 mm 15.75″400 mm 2,250 psi155 bar 125–200 ft·lb169–271 N·m 1/4″upstream 1/4″
660084 8″DN200 XXS 6.63″168 mm 5″127 mm 15.75″400 mm 2,250 psi155 bar 125–200 ft·lb169–271 N·m 1/4″upstream 1/4″
660174 8″DN200 140 6.75″171 mm 5″127 mm 15.75″400 mm 2,250 psi155 bar 125–200 ft·lb169–271 N·m 1/4″upstream 1/4″
660082 8″DN200 120 6.94″176 mm 5″127 mm 15.75″400 mm 2,250 psi155 bar 125–200 ft·lb169–271 N·m 1/4″upstream 1/4″
660175 8″DN200 100 7.19″183 mm 5″127 mm 15.75″400 mm 2,250 psi155 bar 125–200 ft·lb169–271 N·m 1/4″upstream 1/4″
660081 8″DN200 80 7.38″187 mm 5″127 mm 15.75″400 mm 2,250 psi155 bar 150–225 ft·lb203–305 N·m 1/4″upstream 1/4″
660176 8″DN200 60 7.56″192 mm 5″127 mm 15.75″400 mm 2,250 psi155 bar 175–250 ft·lb237–339 N·m 1/4″upstream 1/4″
660080 8″DN200 40/STD 7.73″196 mm 5″127 mm 15.75″400 mm 2,250 psi155 bar 175–250 ft·lb237–339 N·m 1/4″upstream 1/4″
660177 8″DN200 20 7.88″200 mm 5″127 mm 15.75″400 mm 2,250 psi155 bar 175–250 ft·lb237–339 N·m 1/4″upstream 1/4″
660079 8″DN200 10S 8.08″205 mm 5″127 mm 15.75″400 mm 2,250 psi155 bar 175–250 ft·lb237–339 N·m 1/4″upstream 1/4″
660094 10″DN250 160 8.25″210 mm 5″127 mm 16 1/8″410 mm 2,250 psi155 bar 200–275 ft·lb271–373 N·m 1/4″upstream 1″
660095 10″DN250 XXS 8.50″216 mm 5″127 mm 16 1/8″410 mm 2,250 psi155 bar 200–275 ft·lb271–373 N·m 1/4″upstream 1″
660092 10″DN250 100 9.06″230 mm 5″127 mm 16 1/8″410 mm 2,250 psi155 bar 200–275 ft·lb271–373 N·m 1/4″upstream 1″
660091 10″DN250 80 9.31″236 mm 5″127 mm 16 1/8″410 mm 2,250 psi155 bar 200–275 ft·lb271–373 N·m 1/4″upstream 1″
660090 10″DN250 60/XS 9.50″241 mm 5″127 mm 16 1/8″410 mm 2,250 psi155 bar 200–275 ft·lb271–373 N·m 1/4″upstream 1″
660089 10″DN250 40/STD 9.77″248 mm 5″127 mm 16 1/8″410 mm 2,250 psi155 bar 225–300 ft·lb305–407 N·m 1/4″upstream 1″
660086 10″DN250 10S 10.17″258 mm 5″127 mm 16 1/8″410 mm 2,250 psi155 bar 225–300 ft·lb305–407 N·m 1/4″upstream 1″
660106 12″DN300 160 9.75″248 mm 5″127 mm 17″432 mm 2,250 psi155 bar 200–250 ft·lb271–339 N·m 1/4″upstream 1″
660104 12″DN300 XXS 10.37″264 mm 5″127 mm 17″432 mm 2,250 psi155 bar 200–250 ft·lb271–339 N·m 1/4″upstream 1″
660102 12″DN300 80 11.00″279 mm 5″127 mm 17″432 mm 2,250 psi155 bar 200–250 ft·lb271–339 N·m 1/4″upstream 1″
660099 12″DN300 40 11.62″295 mm 5″127 mm 17″432 mm 2,250 psi155 bar 225–275 ft·lb305–373 N·m 1/4″upstream 1″
660178 12″DN300 STD 11.62″295 mm 5″127 mm 17″432 mm 2,250 psi155 bar 225–275 ft·lb305–373 N·m 1/4″upstream 1″
660115 14″DN350 80 12.12″308 mm 6.5″165 mm 18″457 mm 2,250 psi155 bar 225–275 ft·lb305–373 N·m 1/4″upstream 2″
660112 14″DN350 40 12.74″324 mm 6.5″165 mm 18″457 mm 2,250 psi155 bar 225–275 ft·lb305–373 N·m 1/4″upstream 2″
660111 14″DN350 30/STD 12.87″327 mm 6.5″165 mm 18″457 mm 2,250 psi155 bar 225–275 ft·lb305–373 N·m 1/4″upstream 2″
660130 16″DN400 160 12.43″316 mm 6.5″165 mm 19.5″495 mm 2,250 psi155 bar 200–250 ft·lb271–339 N·m 1/4″upstream 2″
660126 16″DN400 80 13.93″354 mm 6.5″165 mm 19.5″495 mm 2,250 psi155 bar 200–250 ft·lb271–339 N·m 1/4″upstream 2″
660124 16″DN400 40/XS 14.62″371 mm 6.5″165 mm 19.5″495 mm 2,250 psi155 bar 225–275 ft·lb305–373 N·m 1/4″upstream 2″
660123 16″DN400 30/STD 14.87″378 mm 6.5″165 mm 19.5″495 mm 2,250 psi155 bar 250–300 ft·lb339–407 N·m 1/4″upstream 2″
660139 18″DN450 80 15.74″400 mm 6.5″165 mm 21″433 mm 2,250 psi155 bar 250–300 ft·lb339–407 N·m 1/4″upstream 2″
660137 18″DN450 40 16.50″419 mm 6.5″165 mm 21″433 mm 2,250 psi155 bar 250–300 ft·lb339–407 N·m 1/4″upstream 2″
660134 18″DN450 STD 16.87″428 mm 6.5″165 mm 21″433 mm 2,250 psi155 bar 275–325 ft·lb373–441 N·m 1/4″upstream 2″
660149 20″DN500 80 17.56″446 mm 6.5″165 mm 22″559 mm 2,250 psi155 bar 225–275 ft·lb305–373 N·m 1/4″upstream 2″
660147 20″DN500 40 18.43″468 mm 6.5″165 mm 22″559 mm 2,250 psi155 bar 175–225 ft·lb237–305 N·m 1/4″upstream 2″
660145 20″DN500 20/STD 18.87″479 mm 6.5″165 mm 22″559 mm 2,250 psi155 bar 225–275 ft·lb305–373 N·m 1/4″upstream 2″
660169 24″DN600 80 21.18″538 mm 6.5″165 mm 23.5″597 mm 2,250 psi155 bar 275–325 ft·lb373–441 N·m 1/4″upstream 2″
660167 24″DN600 40 22.24″565 mm 6.5″165 mm 23.5″597 mm 2,250 psi155 bar 300–350 ft·lb407–475 N·m 1/4″upstream 2″
660164 24″DN600 20/STD 22.87″581 mm 6.5″165 mm 23.5″597 mm 2,250 psi155 bar 275–325 ft·lb373–441 N·m 1/4″upstream 2″

In-service use needs an engineered isolation plan. Never exceed 1,500 psig (103 barg) upstream or 2,250 psig (155 barg) between the seals, and monitor the upstream pressure all the time the plug is installed; stop at once if it changes suddenly. Test only after the weld area has cooled below 180 °F (82 °C). Seam-welded, corroded or scaled pipe may need the bore prepared first. Put anti-seize only on the shaft threads and hardened washers, never on the seals or the pipe bore. After the test, back off the nuts so the seals can relax to their original size.

Applications

Where it works.

Flange-to-pipe weld testing on in-service lines
Oil, gas and chemical process plants
Offshore platforms and shipyards
Tie-in work, plant revamps and flange replacement

My project 0

Need a different size or pressure rating?

Send us the pipe I.D., material and test pressure. We will confirm the right plug and lead time.

Request a quote →